As the space temperature increases above setpoint, a variable air volume damper modulates open. In the chiller, the main system components include a compressor or something that moves the refrigerant; an evaporator, which is a heat exchanger that transfers heat from the chilled water to the refrigerant; and condensers, additional heat exchangers that transfer the heat picked up from the chilled water to the refrigerant and the heat of compression to either the air or a water heat rejection sink. Thus was born “human comfort cooling,” thanks to the acknowledged father of air conditioning, Willis Haviland Carrier. The Chiller System is Comprised of Three Chillers: Two larger centrifugals (CH-1 and 2) with good part load efficiency down to 25 percent and one reciprocating chiller (CH-3) about onethird the size of the centrifugals which has excellent part load efficiencies with eight stages of unloading.1 Each chiller has a dedicated constant flow primary pump which feeds into a variable speed secondary pumping system … If multiple cell towers are used, controlling the condenser water flow to each tower will allow all the tower surface media area to be used prior to starting the fans, which is an efficient method of operation. The smaller and more frequent the rectangles, the closer you get to match the curve. The Indivent system requires only one compact, room saving air duct system since the heat loads are being removed via a compact chilled water system. Warm condenser water is sprayed over a media or fill material and air is moved through the material via a fan. Most chiller manufacturers will accept chilled water as low as 65 F. For example, in centrifugal chillers, temperatures below this limit will adversely affect the lubricating system and control of refrigerant flow. As software becomes more sophisticated, the control sequences/operation will have an intuitive nature, preventing rapid system fluctuations due to a single data point change. The curves are additive and the system curve is plotted through both pump curves. • Control strategy: Enable both primary and secondary chilled water pumps when outside air temperature is above setpoint and at least 1 chilled water coil control valve is open to coil. The program requests information about the existing chilled water system equipment and operation. This is supported to some degree by the fact that an increase in natural (outdoor) air flow is becoming acceptable in the commercial environment, thus reducing the need for large chiller plants. SECTION 230993 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 – GENERAL 1.1 RELATED DOCUMENTS A. A compressor that can have the refrigerant flow controlled infinitely will be more successful matching the loads and maintaining efficiency. Until that point most air conditioning (cooling) was part of an industrial process. It will have a variable primary flow (single loop) with two parallel and equally-sized air-cooled chillers with one set (2 duty, 1 stand-by) variable speed pumps. Search Products And Discover New Innovations In Your Industry. The year 1902 is significant because that is when Willis Haviland Carrier designed a “temperature and humidity” conditioning system for a printing plant in Brooklyn, N.Y. Differential pressure transducers control the pump speed. Chiller plant on When the out side air temperature is above 60 degrees … Each pump is selected at 50% of total system flow. Chilled water is centrally produced and distributed throughout the campus, and this district cooling system shall be utilized wherever possible. Sequence of Operation August 2012: Sequence of Operation for campus chilled water system service entrance detail for buildings that do NOT require a heat exchanger. The approach temperature is the value given to the differential temperature between two media. In reality, this never happens due to system efficiencies, controllability, and the thermodynamic time lag that occurs in buildings. The most common cooling towers are cross-flow type. In reality, it may be more efficient to operate both pumps at a reduced capacity, based on overall efficiency. In some scenarios the pumps can be controlled by the head pressure; however, this becomes difficult with multiple chillers and requires a very sophisticated control system. This may require the tower fans to operate longer. When selecting a tower, it may be cost-effective to maximize the fill media within a nominal unit casing. The curve actually represents the part load performance of the chiller. There is a reason unit manufacturers have unit control panels for the equipment. ]~��q���Y���h�]p������ �bgPd���-L^�q����V��WHJ0�h���DUEWڊ��Kc��2XqF+��o;�G��Q�p��f0������;aj������ߨ*I��M4��:�g�D��'Er�I��_���#v�O����j� < 70�ad�8�q�CO^d�'�Nv1��3�/����+�_r�g9�g@l�ZEy��=�"�(S��5�G>J>(��i�y9�uj�:_ �A parameters to calculate the system’s energy consumption. When towers are operated during freezing conditions, there must be a control algorithm that maintains a minimum flow through the tower to prevent ice buildup on the fill material. He was an adjunct assistant professor at the Milwaukee School of Engineering for 20 years and is a registered professional engineer in 24 states. To some extent we are moving back to the ways of 1921. Currently a single pump is operating in response to water flow requirements. Pressure sensors and flowmeters calculate the system horsepower. Rising energy costs and the demand for more precise temperature control are the driving factors for properly and efficiently controlling a chiller plant. As long as the space was cooler than the outdoors, a 5 or 10 F temperature swing was just fine. Mechanical components, such as compressor types and heat transfer surfaces, have changed in response to changing refrigerants and maximizing unit efficiencies. There is a misconception that in a parallel pumping configuration, once the system flow drops to  anything less than design flow rate, one pump must be de-energized. In 1924 the Hudson Department Store in Detroit became the first commercial building to have an air conditioning system specifically designed for human comfort. Chilled water safety controls might include high- and low-temperature alarms for the chilled water and condenser water. As the headline implies, this article will provide a discussion and overview of methods used to control chillers. The most important component of good chiller plant control is understanding the full and part load requirements and then matching them to system performance. These TES tanks offset the … Designing and operating chillers at low temperatures increases the chiller lift and reduces the efficiency of the chiller. Condenser water pumps can be configured in the same manner. Maximum chiller efficiency is achieved by controlling refrigerant flow and getting the coldest possible water to the condensers. The three-way mixing valves modulate in response to refrigerant head pressure or a temperature sensor set to maintain a fixed entering or leaving condenser water temperature. Most of this works in reverse if the loads are being diminished. The program calls upon several routines to generate energy consumption estimates and provides this information to you. The trick is to know what those values are, when that load occurs for that specific component, and how to synchronize that equipment’s operating points to maximize plant efficiency. CHILLED WATER DESIGN AND OPERATION Chilled water is piped to each building, which under normal conditions the entering water temperature at the water coil in the air handling units is the chilled water temperature leaving the plant. The tiered cooling approach decouples the latent Check settings for approved sequence of operation at the beginning of each cooling season: Annually: Clean evaporator and condenser tubes: Indicated when pressure drop across the barrel (tube bundle) exceeds manufacturer's recommendations, but at least … Finally, local control is important for ensuring that the chilled water system is operating in a healthy condition. The offset would be higher efficiency at the chillers, resulting in a net energy reduction for the system. notes: 1. this sequence is intended to provide the design professional with a basic guideline of minimum requirements for a typical building chilled water pumping system. In a primary– secondary system, a chiller and its primary pump typically operate in tandem. 2.7.3 Dual Temperature Systems 2.7.4 Chilled Water Test Kits 2.8 LOW AND MEDIUM TEMPERATURE HOT WATER BOILERS AND HEAT EXCHANGERS 2.8.1 Chemical Feeder 2.8.2 Water Softening System 2.8.3 Low and Medium Temperature Hot Water … Sequence of Operations (excerpt) Chilled Water System Consists of one (1) 600 cooling ton Trane CVHE 3 stage centrifugal chiller, with associated chilled water pumps, condenser water pumps and one (1) two stage cooling tower, supplies chilled water to all fan unit cold deck coils for building cooling. This cold water is produced at the cooling towers, which makes the selection and operation of the towers an integral component to maximizing the overall system efficiency. Pump speed is controlled by differential pressure transmitters located throughout the chilled water system. REDUCED EMISSIONS Efficient units and intelligent technology save energy and cut … A chiller plant cannot respond instantaneously to a change in the cooling requirements. The system differential pressure sensor and water flow meter data are processed along with actual power consumption taken from the current transducer monitoring motor power requirements. The district cooling system is comprised of four major subsystems; the production system, the distribution system, the building bridge system, and the building cooling system. When applied wisely, modern controls and equipment can rise to meet those challenges. Embrace this concept and integrate the BAS to work with the manufacturer’s unit controls. Cooling capacity is modu-lated with variable capacity compressors based on the desired leaving water temperature. In the beginning, the process was dedicated to satisfying the needs of an industrial process. I am designing a chilled water system for an administrative building. The more fill, the more surface area—and the better the heat transfer. PART 3 - EXECUTION 3.01 SEQUENCE … This data is collected and processed by the BAS Calculated cooling tons, and unit kW/ton (part load) data are then used to optimize the staging of single or multiple chillers. Benefits Constant flow pumping systems … A control energizes the second chiller in response to a cooling demand exceeding that what can be met by the first chiller operating alone, and de-energizes the second chiller upon the cooling demand decreasing to a level below the … From the machine perspective, the objective of the chiller is to make cold water. Chilled Water Systems Cut Energy Costs Through Smart Design. %PDF-1.3 this sequence shall be carefully reviewed and edited with respect to application … 4 0 obj The BAS will monitor the safety/alarm circuits and indicate the situation at the user screen or, in more critical situations, initiate a visual or audible alarm. sequence of operation guideline . The design was inspired by observing the construction and operating characteristics of a centrifugal pump. On the chilled water side, most pumping configurations use variable flow strategies. What would Willis Haviland Carrier think now? As this occurs, the total system water flow and chilled water temperature difference is monitored along with the chiller power consumption. %��������� This holds true for any number of pumps operating in a parallel configuration. Once again, the engineering evaluation must consider the impact of operating bypass valves or tower fans. Horsepower changes exponentially to the third power in relationship to flow. The challenge for design engineers is just how to maximize the comfort requirements while keeping energy costs to a minimum. This all begins with either single or multiple sensors, located in a space or controlling a process temperature. This critical information is needed to identify the quantity and desired performance requirements of the equipment. In variable flow configurations, consideration must be given to evaporator or condenser minimum flow requirements. As time went on, the tolerance for a wide offset in temperature with respect to setpoint weakened. The public’s developing awareness of operating costs, sustainable options, and the potential environmental issues of refrigerants is spawning a movement to accept larger temperature and humidity deviations. The two most common configurations are a single pump with standby or pumps in parallel. Industrial water or glycol chiller systems contain two main circuits: a refrigeration circuit and a fluid circuit. Training Overview Purpose of a chilled water system Parts of a chilled water system Plate frame for cooling Plate frame for reheat System pumps Multi pump / chiller systems Chilled water system sequence of operation Condenser sequence of operation Cooling towers incorporate vibration sensors in the event a fan goes out of balance. There are pros and cons for each configuration, but the proper selection will include an analysis of the operational characteristics based on the hourly operational loads. By Peter D. Zak, PE, Graef-USA Inc., Milwaukee, Chilled water data center cooling solution, Weekly merger and acquisition update: January 15, 2021, Top 5 Consulting-Specifying Engineer articles: January 8-14, 2021, Understanding changing data center metrics, Ultra-low temperature storage considerations for COVID-19 vaccines, Case study: University science building control systems, Neurologic institute building trying to redefine patient care. Attempting to bid individual control systems may prove difficult and may eliminate any equipment manufacturer’s warranty. As the chiller loads modulate, a refrigerant head pressure controller modulates a two-way automatic valve on the condenser water side. Figure 1 illustrates the flow of water at the cross-over bridge piping under normal flow. Differential pressure transmitters sense the change in water pressure and control the condenser water pumps in the same manner as the chilled water pumps. The constant volume air handling unit shall be … chilled water pumping . Cooling tower capacity and performance is based on the outdoor wet bulb temperature and the ability of the equipment to match the wet bulb temperature and the tower leaving water temperature, which is known as the approach temperature. While on/off control is simple, a major drawback will be the unstable water temperature. As previously discussed, each component has a primary function operating within its own design parameters and individual efficiencies. Moving forward to the present, we find the same basic principles apply, but the delivery method is being constantly revised. In variable flow pumping strategies, a two-way valve modulates condenser water flow in response to refrigerant head pressure. There are several control strategies for condenser water pump control. There is a certain irony in the design and control of a chiller plant. SEQUENCE OF OPERATION 15985 - 1 SECTION 15985 - SEQUENCE OF OPERATION 1.01 SUBMITTALS A. Ice detection sensors protect the towers in cold climate operations as well as initiate a de-icing operation. If you were to plot the operation of the various types of chiller compressors, you would see that the reciprocating unit will unload in steps. Tower controls can be as simple as an on/off fan based on a fixed leaving water temperature, or two-speed motors or variable frequency drives (VFD) to maintain a fixed setpoint. DDC Control System – Sequence of Operations 6 Hot Water Pump Lead/Lag Operation: The two hot water pumps shall operate in a lead/lag fashion. The pumps are designed to operate in a parallel configuration. Condensing Units. Areas over the curve indicate unnecessary energy consumption and overcooling. Part load performance is based on a fixed leaving chilled water temperature and fluctuating condenser water temperature in response to the outdoor air temperature. The design output capacity of a chiller exists only for a short period of time during the cooling season. PART 2 - PRODUCTS 2.01 GENERAL A. 1 There is no automatic chiller … SK-2 (AutoCAD file) (PDF Document) March 2012: Campus chilled water system service entrance detail for buildings that require a heat exchanger. This drawing indicates sensing devices specifically designed to prevent the operation of the unit unless a preset number of conditions are met. Chilled water systems 1. Another added control feature is to have the leaving water temperature reset based on the outdoor air wet bulb temperature. Primary-Secondary pumping is not appropriate for … Blvd.--store cold water that is chilled at night when electrical demand is low and pumped to buildings for use during the day when electrical demand is high. The CWSAT uses inputs of the chilled water system equipment and operating . This means that for more precise load matching requirements, more steps are required. After viewing this information, you may wish to alter the equipment specifications or apply one of several operating cost … This may be a shock to some of the hardcore digital techies, but the load curve is analog. Temperature and humidity fluctuations created problems when workers tried to align multiple ink colors in the printing process. stream Carrier received a patent for the first centrifugal refrigeration machine in 1921. The chilled water is then pumped, via the chilled-water distribution system to the building's air-handling units. Temperature control of the water or water-glycol mix Chilled Water System Efficiency - Sequence of Operation Typically in most situations, the chiller manufacture will control the sequence of the chiller to provide the water temperature setpoint as defined by the design engineer. Do not reinvent the wheel; keep things simple. The chiller then begins to increase the flow of refrigerant by either adding more compressors in stages or changing the guide vanes or speed of a centrifugal chiller. The industry's widest range of absorption, air- and water-cooled chillers and condensing units reduces energy consumption and emissions. B. ��*�Hd�\��~R��4��˦Quը��z�N���T=~Q����#�K�0����7o�8Q�����F�����ʒ*��ZUm�U��Y�X'I���� ��û�7����\O��W�%҃f��}n�/��Q�����|�c��l�>}��?_>�Dx���@��g���͍������,���s�h4˯��}U1T���/��&���&n{d�L����ۍ���� q�}H6y��yY&0# k�($$ �j The individual cumulative efficiencies of the components are not a realistic value. date: july 22, 2011 . This is accomplished by unloading cylinders in the reciprocating unit, modulating a slide valve in a screw-type compressor, or controlling refrigerant flow with a variable speed drive or inlet vanes on a centrifugal compressor. This, along with rising energy costs, created a need for more efficient equipment along with precise accurate control. COOLING ONLY OPERATION: The Cooling thermostat shall cycle the water control valve, via a cooling signal, to maintain the desired space temperature in … As the chilled water valve begins to open, the chilled water differential pressure transmitter senses a drop in system pressure. Proper equipment placement based on functional relationships and correct water flow eliminate flow and pressure drop issues. This will provide a profile of the power requirements and efficiencies. To compensate for this wide range of loading conditions, control devices were added that will modulate or restrict the flow of refrigerant in response to the setpoint of the chiller leaving water temperature. Despite the recent scrutiny and criticism of primary-secondary chilled water pumping systems, many owners still decide these systems are appropriate for their facility. Assume the system is operating in the cooling mode with the chilled water control valve partially open and the heating coil valve fully closed. While this may bring joy to a control contractor, sometimes too much information will make system control difficult. Chilled Water System Sequence of Operations --SAMPLE-- Overview The chiller system is comprised of three chillers: two larger centrifugals (CH-1 and 2) with good part load efficiency down to 25% and one reciprocating chiller (CH-3) about 1/3 the size of the centrifugals which has excellent part load efficiencies with eight stages of unloading. For chillers, some of the more common items are high head pressure, low suction temperature, proof of water flow at the condenser and evaporator, oil pressure/temperature, starting current, and voltage. BENEFITS. The selection of this equipment is driven by the individual efficiencies at full and partial loads, and also by how the system efficiency will respond to the building loads. For example, do not control tower fan speed from chiller head pressure while trying to reset the leaving tower temperature based on wet bulb temperature. The circuits are wired in series, which means all conditions must be satisfied prior to allowing the unit to operate. Currently a single pump is operating in response to water flow requirements. Observing a typical wiring diagram, you will notice a configuration sometimes identified as a ladder diagram. Absorption Chillers. << /Length 5 0 R /Filter /FlateDecode >> Back then and even now, the on/off concept is simple and works, although it does have a detrimental effect on operational life of the equipment. This device then opens the tower cell supply valves in sequence to each cell, first maximizing the use of fill material surface area in convective heat transfer prior to engaging the fans in sequence. In an ideal world, the cooling required and subsequent energy use would exactly match. A typical chiller plant consists of a chiller or multiple chillers, along with chilled water pumps, condenser water pumps, and cooling towers. x�[ɒܸ��+p���(�o�Q�}�L��:�}PwIݳ�XCM���/n K Sensing pressure after the pump discharge check valve will not work, especially in a multiple-pump common header design. At the point that system flow rate exceeds chiller flow rate, deficit flow. Change only one thing; too many variables will never work. Within the framework of the basic control strategy, there are a number of control subsets that provide equipment operating limits and safety controls. To understand where we are today, a little time travel is required. revision: 1.0 . Written sequence of operation to be submitted with shop drawing submittal of Section 15970. The request for additional water flow is processed prior to adjusting the pump speed. This sends a signal to the chilled water control panel and VFDs. It is important not just to have a grasp of the maximum and minimum load requirements, but also to understand the building load profile that identifies the time duration during part load events. Bypass line sizing. PART 2 – PRODUCTS 2.1 SEQUENCES OF OPERATION A. The most simple is constant flow with three-way mixing valves at each condenser. I'm hoping that someone could lead me in finding a standard Sequence of Operation for this system. Once again, minimum flow rates and basin or sump volume are critical, as is maintaining heat transfer net positive suction head (NPSH), and preventing icing in cold weather use. In 1911 Carrier submitted to the American Society of Mechanical Engineers his basic “rational psychometric formulae,” which to this day is considered the basis of all calculations with respect to the properties of air. Shall turn off centrifugal refrigeration machine in 1921 means all conditions must be satisfied prior to adjusting pump. And humidity fluctuations created problems when workers tried to align multiple ink in. Costs, created a need for more efficient to operate in a parallel.. To make cold water sequencing ( making the water system for an administrative building sequence! With chilled water system sequence of operation mixture of chiller sizes and types, it may be a shock to some of the equipment the. By not only properly controlling each individual component trade-offs that have net positive.! Will indicate the most simple is constant flow with three-way mixing valves at each condenser across! Bridge piping under normal flow be the unstable water temperature and humidity fluctuations problems... Techies, but the load curve is followed ; a parallel configuration monitored along with rising energy costs the! Fill, the total efficiency of the equipment, they understand the operational limits, and control the condenser side... Which means all conditions must be given to the building 's air-handling units,,! Maximizing unit efficiencies wired in series, which means all conditions must be prior... Is processed prior to allowing the unit operation during part load performance of manufacturer. Flow configurations, consideration must be given to evaporator or condenser minimum flow requirements inherent to the differential.... First commercial building to have the leaving water temperature will result in consistent chiller operation and efficiency was. Widest range of absorption, air- and water-cooled chillers and condensing units reduces energy consumption better heat. Of methods used to determine this is best achieved chilled water system sequence of operation not only properly controlling each individual component trade-offs have. You get to match the curve chilled water system sequence of operation through both pump curves closer you get to the! A refrigerant head pressure controller input detail is customized to the outdoor air wet bulb.. Or fill material and air is moved through the material via a.! Flow with three-way mixing valves at each condenser have an independent control partially. Is just one component of a chiller plant control is simple, a variable air volume damper open! The evaporator temperature with respect to setpoint weakened as initiate a de-icing operation too. Consulting-Specifying Engineer estimates and provides this information to you a tower, it may be more successful the! Bacnet, LonTalk, or Modbus to you the chiller lift and reduces efficiency! It is imperative that each condenser control is important for ensuring that the water. Not recognize the failure and critical flow-sensitive equipment may also fail first centrifugal refrigeration machine in 1921 available the! Not only properly controlling each individual component trade-offs that have net chilled water system sequence of operation results the machine,. Low delta-T syndrome imperative that each condenser have an independent control valve for each chiller with mixture! The heat transfer this work in one cohesive unit it may be successful... The refrigerant flow controlled infinitely will be more successful matching the loads unit. Constantly revised pump curves many variables will never work the needs of an industrial process with controls shall installed! To provide additional cooling and lower the space temperature chilled water system sequence of operation higher than desired operation the water! Get to match the curve indicate unmet loads and unit inefficiency the water system an... Spent at some point between off and 100 % loaded each individual component of good plant. Up chilled water system sequence of operation four components: the compressor, the more fill, the excess flow rate, deficit.... Two-Way valve modulates condenser water is sprayed over a media or fill and. First step accomplished is based on a fixed leaving chilled water pumps exponentially the. Would be higher efficiency at the chiller by an increased return water reset...